UC-3100 Series

Features and Benefits

  • Armv7 Cortex-A8 1000 MHz processor
  • Integrated Wi-Fi 802.11a/b/g/n and LTE Cat. 1 for the US, EU, APAC, and AUS regions
  • Industrial CAN 2.0 A/B protocols supported
  • Robust root file system to prevent the system from being bricked due to a firmware update failure
  • -30 to 70°C system operating temperature
  • Meets the EN 61000-6-2 and EN 61000-6-4 standards for industrial EMC applications
  • Supports Linux real-time OS mode
  • Moxa Industrial Linux with 10-year long-term support

Certifications

Download Datasheet

Introduction

Moxa’s UC-3100 Series computers can be used as edge-field smart gateways for data pre-processing and transmission, as well as for other embedded data-acquisition applications. The UC-3100 Series includes three models, each supporting different wireless options and protocols. The UC-3100’s advanced heat dissipation design makes it suitable for use in temperatures ranging from -30 to 70°C. In fact, the Wi-Fi and LTE connections can be used simultaneously in both cold and hot environments, allowing you to maximize your “data pre-processing” and “data transmission” capability in most harsh environments.

The UC-3100 is more than just a hardware solution. In order to offer a better user experience with a Moxa Arm-based computer, the UC-3100 supports the following software features, allowing you to use the most suitable configuration for your application.

  • High VPN performance; greater than 70 Mbps Ethernet throughput with AES-256 encryption

  • Robust file system to prevent the system from being bricked due to a firmware upgrade failure

  • Cybersecurity auto-configuration system based on IEC 62443

  • Real COM mode to provide a control interface to Moxa’s NPort products

In addition, Moxa provides 10 years of Linux OS support from Moxa’s customer support engineers. With a new version of the Debian repository released on average every 2 to 3 years, long-term Linux OS support helps you create a reliable solution that will be supported now and long into the future.

Applications

  • Remote Terminal Unit (RTU)

  • Data acquisition

  • M2M communication (smart gateway)

  • Digital signage

  • Factory automation

  • In-vehicle monitor/data logger (transportation)

  • Programmable router

  • Energy usage optimization

  • Predictive maintenance

  • Asset management

Appearance

UC-3101

UC-3111

UC-3121

Specifications

Computer
CPU Armv7 Cortex-A8 1 GHz
DRAM 512 MB DDR3
Supported OS Linux Debian 9 kernel 4.4 (Moxa Industrial Linux)
Storage Pre-installed 4 GB eMMC
Storage Slot SD slots x 1 for UC-3111 Series only
Computer Interface
Serial Ports UC-3101/3121 Series: RS-232/422/485 ports x 1, software-selectable (DB9)
UC-3111 Series: RS-232/422/485 ports x 2, software-selectable (DB9)
Ethernet Ports Auto-sensing 10/100 Mbps ports (RJ45 connector) x 2
USB 2.0 USB 2.0 hosts x 1, type-A connectors
Cellular Antenna Connector SMA x 2
Wi-Fi Antenna Connector RP-SMA x 2 for UC-3111/UC-3121 Series only
Number of SIMs 2
SIM Format Nano
Console Port RS-232 (TxD, RxD, GND), 4-pin header output (115200, n, 8, 1)
Ethernet Interface
Magnetic Isolation Protection 1.5 kV (built-in)
Cellular Interface
Band Options US Models:
LTE Bands: 2, 4, 5, 12 (700, 850, 1700/2100 (AWS) and 1900 MHz)
UMTS Bands: 5, 4, 2 (WCDMA/FDD 850, 1700/2100 (AWS) and 1900 MHz)
Carrier Approval: AT&T
EU Models:
LTE Bands: 1, 3, 8, 20, 28 (700, 800, 900, 1800, 2100 MHz) GSM Bands: 900 and 1800 MHz
AU/NZ Models:
LTE Bands 3, 5, 8, 28 (1800, 850, 900, 700 MHz) UMTS Bands 1, 5, 8 (WCDMA/FDD 2100, 850, 900 MHz)
WLAN Interface
WLAN Standards 802.11a/b/g/n
Frequency Band 2.4 GHz
5 GHz
Serial Interface
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
CAN Interface
Connector DB9 male
Baudrate 10 to 1000 kbps
Signals CAN_H, CAN_L, CAN_GND, CAN_SHLD, CAN_V+, GND
Isolation 2 kV (built-in)
LED Indicators
System Power x 1
LAN 1 per port (10/100 Mbps)
Serial 1 per port (Tx, Rx)
Wireless Signal Strength 3 for UC-3101 Series
6 for UC-3111/UC-3121 Series
CAN 2 per port (Tx, Rx)
Power Parameters
Input Voltage 9 to 36 VDC
Power Consumption 6 W (max.)
Input Current 500 mA @ 12 VDC
Physical Characteristics
Housing Metal
Installation DIN-rail mounting, Wall mounting (with optional kit)
Weight Product only: 550 g (1.22 lb)
Dimensions (without ears) 128.5 x 89.1 x 26 mm (5.06 x 3.51 x 1.02 in) for UC-3101 Series
128.5 x 89.1 x 41 mm (5.06 x 3.51 x 1.61 in) for UC-3111/UC-3121 Series
Environmental Limits
Operating Temperature -30 to 70°C (-22 to 158°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Vibration 5 Grms @ IEC 60068-2-64, random wave, 5-500 Hz, 1 hr per axis (without any USB devices attached)
Shock IEC 60068-2-27
Standards and Certifications
EMC EN 61000-6-2/-6-4
EMI CISPR 22, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Cellular Standards EN 301511
EN 3011908-1
MPE SAR
EN 301489-1-1
EN 301489-24
AS/NZS S042
AS/NZS 60950
Radio Frequency PTCRB, FCC
Safety UL 60950-1
WLAN Standards EN 301489-1-17
EN 300328
EN 301893
Green Product RoHS, CRoHS, WEEE
Hazardous Locations Class I Division 2, IECEx, ATEX
MTBF
Tijme 600,447 hrs
Warranty
Warranty Period 5 years