Ethernet Interface |
|
10/100BaseT(X) Ports (M12 D-coded 4-pin female connector) |
TN-5308 Series non-PoE models: 8 |
PoE Ports (10/100BaseT(X), M12 D-coded 4-pin female connector) |
TN-5308-4PoE Series: 4 |
|
TN-5308-8PoE Series: 8 |
Standards |
IEEE 802.3 for 10BaseT |
|
IEEE 802.3u for 100BaseT(X) |
|
IEEE 802.3x for flow control |
|
TN-5308 Series PoE models: IEEE 802.3af for PoE |
Power Parameters |
|
Input Current |
TN-5308-LV Series: 0.19 A @ 12 VDC, 0.10 A @ 24 VDC, 0.05 A @ 48 VDC |
|
TN-5308-MV Series: 0.033 A @ 72 VDC, 0.024 A @ 96 VDC, 0.021 A @ 110 VDC |
|
TN-5308-4PoE Series: 1.6 A @ 48 VDC |
|
TN-5308-8PoE Series: 2.9 A @ 48 VDC |
Input Voltage |
TN-5308-LV Series: 12 to 48 VDC |
|
TN-5308-MV Series: 72 to 110 VDC |
|
PoE models: 48 VDC |
Max. PoE Power Output per Port |
TN-5308 Series PoE models: 15.4 W |
No. of Power Inputs |
1 |
Operating Voltage |
TN-5308-LV Series: 8.4 to 60 VDC |
|
TN-5308-MV Series: 50.4 to 137.5 VDC |
|
TN-5308 Series PoE models: 46 to 50 VDC |
Power Connector |
TN-5308-LV Series and TN-5308 Series PoE models: M12 A-coded male connector |
|
TN-5308-MV Series: M23 connector |
Physical Characteristics |
|
Housing |
Metal |
IP Rating |
IP40 |
Dimensions |
TN-5308-LV Series: 60 x 216.6 x 36.1 mm (2.36 x 8.53 x 1.42 in) |
|
TN-5308-MV Series: 60 x 216.6 x 53.8 mm (2.36 x 8.53 x 2.12 in) |
|
TN-5308-4PoE Series: 60 x 216.6 x 48.7 mm (2.36 x 8.53 x 1.91 in) |
|
TN-5308-8PoE Series: 60 x 216.6 x 52.9 mm (2.36 x 8.53 x 2.1 in) |
Weight |
TN-5308-LV Series: 485 g (1.07 lb) |
|
TN-5308-MV Series: 685 g (1.51 lb) |
|
TN-5308-4PoE Series: 675 g (1.49 lb) |
|
TN-5308-8PoE Series: 970 g (2.14 lb) |
Installation |
DIN-rail mounting (with optional kit), Wall mounting |
Protection |
TN-5308 Series -CT models: PCB conformal coating |
Environmental Limits |
|
Operating Temperature |
Standard Models: -25 to 60°C (-13 to 140°F) |
|
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Altitude |
2000 m |
Standards and Certifications |
|
Freefall |
IEC 60068-2-32 |
EMC |
EN 55032/24 |
EMI |
CISPR 32, FCC Part 15B Class A |
EMS |
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV |
|
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m |
|
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV |
|
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV |
|
IEC 61000-4-6 CS: 10 V |
|
IEC 61000-4-8 PFMF |
Environmental Testing |
IEC 60068-2-1, EN 50155 |
|
IEC 60068-2-14, EN 50155 |
|
IEC 60068-2-2, EN 50155 |
|
IEC 60068-2-30, EN 50155 |
International Approval |
RCM |
Railway |
EN 50121-4, EN 50155 |
Railway Fire Protection |
EN 45545-2 |
Safety |
EN 60950-1, UL 508 |
Salt Spray Test |
IEC 60068-2-11, EN 50155 |
Shock |
IEC 60068-2-27, IEC 61373, EN 50155 |
Vibration |
IEC 60068-2-64, IEC 61373, EN 50155 |
Declaration |
|
Green Product |
RoHS, CRoHS, WEEE |
MTBF |
|
Time |
TN-5308-LV Series: 2,099,286 hrs |
|
TN-5308-MV Series: 2,590,858 hrs |
|
TN-5308-4PoE Series: 252,075 hrs |
|
TN-5308-8PoE Series: 308,392 hrs |
Standards |
Telcordia SR332 |
Warranty |
|
Warranty Period |
5 years |
Details |
See www.moxa.com/warranty |