RowCool 29/43 kW, Chilled Water

Introduction

Product available regions :
Because product specifications vary slightly from region to region, please download your local leaflet or visit your local website for detailed product information.

EMEA North America South America SEA India China Taiwan South Korea
● (43kW)

RowCool for effective heat removal in data centers

As the power density increases in modern data centers, traditional precision air conditioning fails to provide complete cooling for the following situations:

  • Load variations for peak and off-peak period
  • High power density
  • Uneven heat distribution

The Delta InfraSuite Precision Cooling RowCool Chilled Water can effectively solve the above problems.

 

Applications:

  • High power density rack area
  • Environment that requires precise environmental control

 

Front and rear view of RowCool 29 kW


Features

High Availability

Built-in dual power supply with dual input for better power reliability
Rectifiers and fan that support hot swappable, greatly reducing maintenance time
Panel made of cold-rolled steel plate and coated with surface electrostatic spraying
Built-in leakage detector capable of leak display and alert
Modular rack design readily expandable by load to enable quick configuration
Built-in manual dehumidifying for quick and precise dehumidification
Supporting group control and used as backup

High Flexibility

Chilled water pipe suitable for both top and bottom insertion, with flexible configuration as required
Wheels on bottom for easy moving to locations that need cooling
Disposable filter with high efficiency (MERV 8 ASHRAE 52.2, 45mm); washable MERV 1 filter is available for purchase to save cost
Remote monitoring can be carried out through SNMP card, providing more comprehensive system protection

High Efficiency

To comply with the high power density of racks, the RowCool series cooling capacity can increase up to 60kW (HCH1870) without changing footprint
– for RowCool 43kW
When Applied to the high temperature settings of inlet water, outdoor units save on power consumption by up to 15~20% when the chiller water temperature increases from 5°C to 12°C
Continuously variable speed fan design for energy saving
Cooling system capable of variable flow control for energy saving

Built-in vortex wafer flow meter capable of monitoring chilled water flow that renders easy display of system status

Technical Specifications

Model
HC5990
Power
Rated voltage
1-phase 100-240 Vac
Fan
Type
EC
Communication
Dry contact x 4
Conformance
CE, EN55022 Class A
Dimensions (W x H x D)
430 x 400 x 54 mm
Weight
5.6 kg

All specifications are subject to change without prior notice.Delta InfraSuite Precision Cooling - Air Distribution Unit

Downloads

https://www.deltapowersolutions.com/media/download/Leaflet-InfraSuite-RowCool-29-43-70-95-Chilled-Water-en-us.pdf

https://www.deltapowersolutions.com/media/download/Leafket-InfraSuite-RowCool-43kW-Chilled-Water-UL-en-na.pdf

https://www.deltapowersolutions.com/media/download/Manual-InfraSuite-RowCool-29-43kW-en-us.pdf

https://www.deltapowersolutions.com/media/download/Brochure-Infrasuite-en-us.pdf