RoomCool F Series

The Delta RoomCool F series, using electronically commuted (EC) fans, are room-based precision cooling of modern data center developed specifically for medium or small sized data centers. The Delta RoomCool F series’ design achieves a high Annual Energy Efficiency Ratio (AEER), as well as high reliability and flexibility. As most data centers use traditional air supplies under a raised floor, the new approach of the F series offers both traditional and modern options. The F series is the best choice for medium or small sized data centers, for both building new data center facilities and retrofits.

Delta Precision Cooling - RoomCool F series, Air-Cooled


Benefits of InfraSuite Device Master

Free to Download
InfraSuite Device Master is free to download with 5 nodes by default for monitoring your devices. Various infrastructure facilities such as power and cooling in a data center can be monitored.

Real-Time Monitoring
Users can gather the latest status of critical facilities in a data center through the system screens of InfraSuite Device Master. InfraSuite Device Master also lets you view all of a site’s device information and query history and events at the same time, even for multiple sites in different countries.

Easy to Deploy
The download file is ready on the Delta Software website. InfraSuite Device Master is easy to install on your server or PC, with software designed for quick installation and implementation.

Migrate to InfraSuite Manager (DCIM)
If you are not only looking for device monitoring but also a complete DCIM solution, InfraSuite Device Master is the easiest way of migrating to InfraSuite Manager, which is Delta fully featured DCIM software solution.

InfraSuite Device Master - monitoring application

Features

High Efficiency

Fans can be configured under a raised floor to reduce fan power consumption by about 20%.

All series use EC fans with variable fan speeds set according to static pressure of data centers’ requirement, optimizing the operation and performance of the precision cooling system.

Smart fuzzy control of condenser fan operation is more stable and energy saving compared to traditional controls.

Highly efficient scroll compressor with various energy-saving optimization designs provides traditional data centers with outstanding AEER performance.

High Availability

Compact design with full front access maintenance minimizes footprint and maintenance space and creates maximum available IT space in the same data center area.

Dual compressor system models offer internal redundancy function for continuous system operation when other systems malfunction.

Color graphical touch panel offers user-friendly, interactive operation.

User-friendly 7-inch color touch screen display supporting graphic interface.

Smart group control offers rotation, back up, competition free, and soft start functions.

Used with Delta ADU provides sufficient cooling capacity for some high power density racks.

High Flexibility

Depending on raised floor height or customer preference, fan installation can be below the raised floor or inside the RoomCool machine.

Installing fans directly does not require additional accessories, settings, or tools. Fan installation under the floor reduces power consumption and noise.

Full front access maintenance does not require rear maintenance space. Installation against a wall to fit with the layout design of the data center is possible for maximum flexibility.

Multiple communication interfaces satisfy the surveillance and communication needs for a variety of data centers.

Condensers equipped with AC fans are also available for budget customers.

Technical Specifications

Model
HCD6640-20 / HCD6660-30 / HCD6660A-35 / HCD6670A-40 / HCD6680A-50 / HCD66A0A-60 / HCD66B0A-70
Air flow
Down flow
Input Power
3-phase 380-415V, 50 Hz
Capacity *
HCD6640-20
Total capacity : 17.8 kW
Sensible capacity : 16.0 kW
HCD6660-30
Total capacity : 25.7 kW
Sensible capacity : 23.1 kW
HCD6660A-35
Total capacity : 34.1 kW
Sensible capacity : 28.3 kW
HCD6670A-40
Total capacity : 36.8 kW
Sensible capacity : 30.5 kW
HCD6680A-50
Total capacity : 48.5 kW
Sensible capacity : 43.7 kW
HCD66A0A-60
Total capacity : 55.1 kW
Sensible capacity : 49.6 kW
HCD66B0A-70
Total capacity : 65.8 kW
Sensible capacity : 59.2 kW
Compressor
Type
Scroll compressor
Refrigerant
R410A
Fan
Type : EC
Heater
Type : Electronical heater
Humidifier
Type : Electrode humidifier
Filter
Type : MERV 8
Conformance
CE
Display
Touch panel
Communication
RS-485 x 1, Input dry contact x 2, Output dry contact x 6, SNMP x 1
Dimensions (WxDxH)
HCD6640-20 : 852 x 850 x 1970 mm
HCD6660-30 : 852 x 850 x 1970 mm
HCD6660A-35 : 852 x 850 x 1970 mm
HCD6670A-40 : 852 x 850 x 1970 mm
HCD6680A-50 : 1702 x 850 x 1970 mm
HCD66A0A-60 : 1702 x 850 x 1970 mm
HCD66B0A-70 : 2052 x 850 x 1970 mm
Weight
HCD6640-20 : 250 kg
HCD6660-30 : 288 kg
HCD6660A-35 : 311 kg
HCD6670A-40 : 314 kg
HCD6680A-50 : 520 kg
HCD66A0A-60 : 527 kg
HCD66B0A-70 : 595 kg
* Cooling capacity is measured at 24°C return air temperature, 50% relative humidity and 45°C condensing temperature.All specifications are subject to change without prior notice.

Outdoor Unit
Model
HFC6B40-09S
Input Power
1-phase 220-230V, 50Hz
Fan
Type : AC
Dimension (W x D x H)
1115 x 1100 x 1090 mm
Weight
79 kg
Model
HFC6B40-11S
Input Power
1-phase 220-230V, 50Hz
Fan
Type : AC
Dimension (W x D x H)
1315 x 1100 x 1090 mm
Weight
89 kg
Model
HFC6B40-13S
Input Power
1-phase 220-230V, 50Hz
Fan
Type : AC
Dimension (W x D x H)
1515 x 1100 x 1090 mm
Weight
99 kg
Model
HFC6B50-15S
Input Power
1-phase 220-230V, 50Hz
Fan
Type : AC
Dimension (W x D x H)
1715 x 1100 x 1090 mm
Weight
107 kg
Model
HFC6B70-17D
Input Power
1-phase 220-230V, 50Hz
Fan
Type : AC
Dimension (W x D x H)
1915 x 1100 x 1090 mm
Weight
142 kg
Model
HFC6B70-20D
Input Power
1-phase 220-230V, 50Hz
Fan
Type : AC
Dimension (W x D x H)
2215 x 1100 x 1090 mm
Weight
154 kg
Model
HCC6C40-09S
Input Power
3N~, 380-415V, 50/60Hz
Fan
Type : EC
Dimension (W x D x H)
1115 x 1100 x 1090 mm
Weight
82 kg
Model
HCC6C40-11S
Input Power
3N~, 380-415V, 50/60Hz
Fan
Type : EC
Dimension (W x D x H)
1315 x 1100 x 1090 mm
Weight
92 kg
Model
HCC6C50-13S
Input Power
3N~, 380-415V, 50/60Hz
Fan
Type : EC
Dimension (W x D x H)
1515 x 1100 x 1090 mm
Weight
102 kg
Model
HCC6C50-15S
Input Power
3N~, 380-415V, 50/60Hz
Fan
Type : EC
Dimension (W x D x H)
1715 x 1100 x 1090 mm
Weight
110 kg
Model
HCC6C70-17D
Input Power
3N~, 380-415V, 50/60Hz
Fan
Type : EC
Dimension (W x D x H)
1915 x 1100 x 1090 mm
Weight
148 kg
Model
HCC6C70-20D
Input Power
3N~, 380-415V, 50/60Hz
Fan
Type : EC
Dimension (W x D x H)
2215 x 1100 x 1090 mm
Weight
160 kg

Downloads

https://www.deltapowersolutions.com/media/download/Leaflet-InfraSuite-RoomCool-F-series-Air-cooled-en-us.pdf

https://www.deltapowersolutions.com/media/download/Manual-InfraSuite-RoomCool-DXA-50Hz-en-us.pdf

https://www.deltapowersolutions.com/media/download/Brochure-Infrasuite-en-us.pdf