Modular UPS – DPH Series 50- 300/500/600 kW

Introduction

Product available regions :
Because product specifications vary slightly from region to region, please download your local leaflet or visit your local website for detailed product information.

EMEA North America South America SEA India China Taiwan South Korea
The world’s highest power density providing ultimate MW power protection with leading power performance and superior reliabilityIn this IT intensive world with heavy data traffic driven by cloud, 4G/5G and media streaming applications, IT managers are facing the challenges of increasing rack power density and limited data center space. Delta’s innovative modular UPS technologies provide the answer to customers’ demand for high power density, high power performance, and ultimate availability. The brand-new Delta Modulon DPH series UPS 50-300/500/600kVA achieves the industry’s leading power density of 50kW per module, offering the smallest footprint and best space utilization. The Modulon DPH Series UPS is the ideal modular power protection for MW data centers to achieve total cost of ownership (TCO) optimization.

User-friendly 10" color touch screen; Fully modularized and hot-swappable design

Applications:

DPH series 50-500kVA UPS - Applications


Features

Excellent Power Performance
The industry’s leading power density per module at 50kW in 3U space, and the smallest footprint for 500kVA in a single rack and 600kVA in two racks, to achieve the best utilization compared with its peers
High AC-AC efficiency up to 96.5% and ECO mode to 99% resulting in marked energy cost savings
Green mode featuring a load aggregation function optimizes system efficiency
Ultimate Availability
Fully modularized design and hot-swappable key modules ensure Mean Time To Repair (MTTR) close to zero without downtime risk
Redundant components and dual CAN bus delivers highest system availability and avoids single point of failure
Modular UPS grows with your business by parallel expansion up to 8 units for 4.8MVA of total power capacity
High Manageability
User-friendly 10” color touch screen enables easy local UPS management
Environment information such as security, water, fire, and temperature can be integrated into the UPS for easy monitoring via the LCD of the UPS
If the UPS is equipped with an external battery management system, the battery information can be integrated into the UPS and monitored via the LCD of the UPS

Technical Specifications

Model
DPH 300 System
DPH 500 System
DPH 600 System
Power Rating
DPH 300 System
100,150,200,250,300 kVA
100,150,200,250,300 kW
Power Module Quantity : Up to 6 units
DPH 500 System
300,350,400,450,500 * kVA
300,350,400,450,450 kW
Power Module Quantity : Up to 9 units
DPH 600 System
500,550,600 kVA
500,550,600 kW
Power Module Quantity : Up to 12 units
Input
Nominal Voltage
220/380V, 230/400V, 240/415V (3-phase, 4-wire + G)
Voltage Range
176 ~ 276 Vac (full load)
Current Harmonic Distortion
< 3% **
Power Factor
> 0.99
Frequency Range
40 ~ 70 Hz
Output
Voltage
220/380V, 230/400V, 240/415V (3-phase, 4-wire + G)
Voltage Harmonic Distortion
≤ 0.5% (linear load)
Voltage Regulation
±1% (static)
Frequency
50/60 ± 0.05 Hz
Overload Capability
≤ 125% : 10 minutes
≤ 150% : 1 minute
> 150%: 1 second
Display
10” color touch screen
Interface
Standard
RS232 x 1, Parallel port x 4, USB type A x 2, USB type B x 1, MODBUS x 1, Smart slot x 1, REPO x 1, EPO x 1, Input dry contact x 4, Output dry contact x 6, External battery temperature dry contact x 4, External switch/breaker status dry contact x 4, BMS (RJ45) x 1, Ethernet x 1
Optional
Relay I/O card, Battery cabinet temperature sensor cable
Conformance
Safety
CE
Efficiency
AC-AC Mode
Up to 96.5%
ECO Mode
99%
Battery
Nominal Voltage
±240 Vdc
Charge Voltage
±272V (adjustable from 204V to 312V)
Protection of Battery Deep Discharge
Yes
Environment
Operating Temperature
0 ~ 40 ℃
Relative Humidity
0 ~ 90% (non-condensing)
Audible Noise (at one meter)
DPH 300 System : < 75 dB
DPH 500 System : < 80 dB
DPH 600 System : < 85 dB
IP Protection
IP 20
Others
Parallel Redundancy and Expansion
Module and system redundancy, Maximum 8 units
Emergency Power Off
Remote (default) and local (optional)
Battery Start
Yes
Physical
Dimensions (W x D x H)
DPH 300 System : 600 x 1100 x 2000 mm
DPH 500 System : 600 x 1100 x 2000 mm
DPH 600 System : 1200 x 1100 x 2000 mm
Weight : UPS System (without power modules)
DPH 300 System : 311 kg
DPH 500 System : 317 kg
DPH 600 System : 605 kg
Weight : 50kW Power Module (optional)
36 kg
* The power module’s power rating is adjustable to either 50kVA or 55.6kVA via touch panel.
** When input vTHD is less than 1%.All specifications are subject to change without prior notice.

Downloads

https://www.deltapowersolutions.com/media/download/Brochure-UPS-DPH-300-500-600kVA-en-us.pdf

https://www.deltapowersolutions.com/media/download/Leaflet-UPS-DPH-300-500-600kVA-en-us.pdf

https://www.deltapowersolutions.com/media/download/Manual-UPS-DPH-100-300kVA-50kw-en-us.pdf

https://www.deltapowersolutions.com/media/download/Manual-UPS-DPH-200-500kVA-en-us.pdf

https://www.deltapowersolutions.com/media/download/Manual-UPS-DPH-200-600kVA-en.pdf