InfraSuite Manager (DCIM)

Introduction

Product available regions :

EMEA North America South America SEA India China Taiwan South Korea
Delta InfraSuite Manager is the fully featured Data Center Infrastructure Management (DCIM) software solution to deliver automation and visibility into the data center and increase the ease of management on a comprehensive platform. InfraSuite Manager optimizes the performance and life cycle management of the data center.

Benefits of InfraSuite Manager

Central View from One Platform
InfraSuite Manager provides users a central view to monitor all of the critical information for a data center based on a single real-time platform.

Cost Effective
Organizations with corporate operation of cost efficiency initiatives can also look to Data Center Infrastructure Management (DCIM) to better manage and optimize resource use across their entire infrastructure, as well as help lower their impact on the environment. PUE (Power Usage Effectiveness) is improved and costs are reduced accordingly.

Increased Availability
By monitoring critical information in the data center, the availability of the data center has been increased. InfraSuite Manager offers advanced alert algorithms across the infrastructure. It helps the data center mitigate the risk of downtime.

Sustainability Management
Having insight into the future of the data center’s day-to-day operations, and understanding how to optimize the data center’s resource allocation is invaluable to a business. InfraSuite Manager not only enhances capacity and asset management but also improves overall productivity, which can extend the data center life cycle.

 

Empower Your Data Center

For Facilities Managers

InfraSuite Manager (DCIM) - empower datacenter facilities managers
  • Overall layout of your data center
  • Overall environment mapping or profile of your data center
  • All equipment status
  • Chiller plant status and profile
  • Power diagrams
  • Alarm notification and reporting

For IT Managers

InfraSuite Manager (DCIM) - empower datacenter for IT managers
  • Access control and surveillance
  • Asset management
  • Rack utilization, rack U-space, weight, power load and network port for each rack
  • Multiple site management
  • Alarm notification, reporting and schedule
  • IPMI

For Chief Information Officers CIOs

InfraSuite Manager (DCIM) - empower datacenter for Chief Information Officers CIO
  • Real time and historical PUE
  • Electricity cost and billing
  • Overall capacity utilization
  • Work order progress and approval process
  • Alarm notification and reporti

Features

Management Philosophy for Data Center Optimization Management Philosophy for Data Center Optimization

Measurement
Measure and monitor the overall data center environment in real-time
from a central dashboard

Analytics
Create a virtual model of the infrastructure to digitally map the
relationships between all these components

Plan
Manage the data center better based on insightful historical
information and trend analysis with well-grounded planning

Action
Define actionable solutions and configurations to execute

 

Base Model (Operation Platform) Base Model (Operation Platform)

The base model of the InfraSuite Manager provides real-time critical information for a data center across floors or locations. It also gives recommendations on how to resolve issues, and offers a built-in report generator tool and template that provide device information and trend charts in the reports. The base model is the fundamental monitoring platform and extensional function modules can be added according to the demands of enterprises or organizations. The communication architecture of InfraSuite Manager uses Master/Slave and Browser/Server architecture for the Windows client and web browser user interface.

Overview of Data Center - Temperature

▲ Overview of Data Center – Temperature

PUE Energy Module PUE Energy Module

The Energy Module of the InfraSuite Manager contains the functions of energy measurement, PUE calculation, electricity tariff formula, and historical data analysis. In addition, it includes organizational energy classification and management mechanism. With time and experience operating this system, datacenter managers develop greater agility for managing energy consumption. This module can transform energy consumption data collected from power meters, UPS (Uninterruptible Power Supply), PDU (Power Distribution Unit) and environment detectors into dynamic charts and graphs, including line charts, bar charts, and pie charts based on user preference.

InfraSuite Manager - DCIM - Dashboard of PUE

▲ Dashboard of PUE

Energy Analysis Module Energy Analysis Module

Energy Analysis is not just for a single site but for the entire organization. The electricity tariff formula can be customized for each department. In terms of detailed energy analysis, Delta offers diverse scenario analyses, including energy usage KPI, comparison, energy combination analysis, abnormal energy usage ranking, and energy usage estimation.

InfraSuite Manager - DCIM - The Hierarchy of Energy Analysis

▲ The Hierarchy of Energy Analysis

Asset Module Asset Module

Asset Module offers graphical views of assets in every single rack in the data center. This makes it easy to quickly identify the power path and network topology map. In the case of assets without proper management, it often leads to a higher mean time to repair (MTTR) and lowering the availability of the data center’s equipment.

InfraSuite Manager - DCIM - Asset Module - Rack Management

▲ Asset Module – Rack Management

Capacity Module Capacity Module

Capacity Module allows data center managers to plan for the future more effectively through the use of detailed data on rack space, weight, network, power and cooling capacity in the data center. For example, Capacity Module helps data center managers evaluate resource consumption, making it easier for them to plan and decide on the future allocation and most suitable installation locations for IT devices.

InfraSuite Manager - DCIM - Automatic Availability Calculation

▲ Automatic Availability Calculation

Work Order Module Work Order Module

The Work Order Module provides a highly customizable platform that enables users to design work order templates for different management purposes. Different variables such as names, types, priority, schedule, roles of tasks can then be set by the administrator. This helps users not only simplify and integrate the process of change management, but also extends the life cycle of data center operation.

InfraSuite Manager - DCIM -The Process of Change Management

▲ The Process of Change Management

Asset Inspection Module Asset Inspection Module

The Asset Inspection Module of the InfraSuite Manager is used with a user-friendly mobile app which makes it smarter and more efficient for the inspector to complete his/her inspection process. Customizable templates can be designed for different types of assets. Users can also upload photos of the inspected assets to InfraSuite Manager. Unique QR codes of each asset can be generated by the system, making the tasks more intuitive.

InfraSuite Manager - DCIM - The flow of Inspection Execution and Review

▲ The flow of Inspection Execution and Review

Technical Specifications

InfraSuite Manager is a DCIM software system that integrates infrastructure, power, energy, cooling, environmental monitoring, security, assets, capacity, and work order for data center management.

Delta set up this technical support platform to assist partners with technical and maintenance support for building their data centers.

Downloads

https://www.deltapowersolutions.com/media/download/Leaflet-InfraSuite-Manager-en-us.pdf

https://www.deltapowersolutions.com/media/download/Manual-InfraSuite-Manager-en-us.pdf

https://www.deltapowersolutions.com/media/download/Brochure-Infrasuite-en-us.pdf

System Requirement

Server
Hardware
CPU: > 2GHz
Memory: ≥ 8G
Free HD Space: 500G mirrored
Software
Support OS: Windows 7, 8, 10, Windows Server 2008, 2012, 2016
Windows Application UI
Hardware
CPU: > 2GHz
Memory: ≥ 4G
Software
Support OS: Windows 7, 8, 10, Windows Server 2008, 2012, 2016
Web Monitor UI
Hardware
CPU: > 2GHz
Memory: ≥ 4G
Software
Recommended Web Browser: Microsoft Internet Explorer v11, Google Chrome v30, Mozilla Firefox v23 and Safari v5.