ICF-1170I Series

Features and Benefits

  • Transmits data up to 2 km over optical fiber
  • Converts CAN signals to fiber and fiber to CAN signals
  •  Baudrate up to 1 Mbps
  •  Dual power inputs for redundancy
  •  DIP switch for 120 ohm terminal resistance
  •  DIP switch for fiber test mode
  •  LEDs for Fiber Tx, Fiber Rx, Power 1, Power 2
  •  Wide-temperature model available for -40 to 85°C environments
  •  Fully compatible with the ISO 11898 standard

Certifications

Download Datasheet

Introduction
The ICF-1170I Series CAN-to-fiber converters are used to convert CAN signals from copper to optical fiber. The converters come with 2 kV optical isolation for the CAN bus system and dual power inputs with alarm contact relay to ensure that your CAN bus system will remain online.

Fiber Test Mode
Fiber Test Mode can be used to test the fiber cable between two ICF-1170I units, and it provides a simple way to determine if the fiber cable is transmitting data correctly. When in Fiber Test Mode, the fiber transceiver (Tx) will continuously send out a data signal and the Fiber Tx LED will light up. On the other side of the connection, when the ICF-1170I fiber transceiver (Rx) receives the data signal from the Tx side, the Fiber Rx LED will light up.

Specifications

Serial Interface
Optical Fiber ICF-1170I-M-ST: 100BaseFX ports (multi-mode ST connector)
Optical Fiber
Low-speed Fiber Module Multi-mode
Fiber Cable Requirements 50/125 µm, 800 MHz
62.5/125 µm, 500 MHz
Typical Distance 2 km
Wavelength Typical (nm) 850
TX Range (nm) 840 to 860
RX Range (nm) 800 to 900
Optical Power TX Range (dBm) 0 to -5
RX Range (dBm) 0 to -20
Link Budget (dB) 15
Dispersion Penalty (dB) 1
CAN Interface
Isolation 2 kV (built-in)
No. of Ports 1
Signals CAN_L, CAN_H, CAN Signal GND
Terminator N/A, 120 ohms (by DIP)
Power Parameters
Input Current 221 mA @ 12 to 48 VDC
Input Voltage 12 to 48 VDC
No. of Power Inputs 2
Overload Current Protection Supported
Power Consumption 221 mA @ 12 to 48 VDC
Physical Characteristics
Housing Metal
IP Rating IP30
Dimensions 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
Weight 178 g (0.39 lb)
Installation DIN-rail mounting
Environmental Limits
Operating Temperature ICF-1170I-M-ST: 0 to 60°C (32 to 140°F)
ICF-1170I-M-ST-T: -40 to 85°C (-40 to 185°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standard and Cerifications
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
Environmental Testing IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
Safety EN 60950-1, IEC 60950-1
Vibration IEC 60068-2-6
MTBF
Time 792,085 hrs
Standards Telcordia (Bellcore), GB
Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty