DPH Series 25-75/150/200 kW

The modular UPS ideal for medium-sized datacenters

Introducing the next generation of modular uninterruptible power supply (UPS) systems designed for ultimate availability, excellent performance, high efficiency, and ideally suited for medium-sized datacenters.The Modulon DPH Series UPS is a modular UPS used extensively for critical operations, since it provides 25% more power output compared to power factor 0.8 UPS systems. Designed for the most stringent datacenter requirements, the Modulon DPH Series offers the highest possible availability. With its modular structure, the true on-line, double conversion, three-phase Modulon DPH Series UPS system offers a scalable architecture for optimal power designs. It provides 25kW to 200kW of uninterruptible power with additional 800kW capacity in parallel.

The Modulon DPH Series’ scalable architecture is available in a 19″ enclosure, and supports vertical and horizontal expansion for versatile installation arrangements. Integration of your power distribution can take shape within the same rack or in parallel rack enclosures. Optimal placement is ultimately decided by the needs of the datacenter, not the limitations of the UPS system.

Built-in redundancy guarantees a continued power supply for mission critical applications, and the fully fault-tolerant design of the Modulon DPH Series offers self-redundancy for the control mechanism, cooling and power modules. Mean time to repair (MTTR) is close to zero, due to hot-swappable functionality for all critical components. In the event of failure by the main module, full control logic enables the system to self-synchronize and switch to the backup, for a seamless transition with no disruption to operations.

Delta’s Modulon DPH Series UPS provides one of the highest efficiency ratings in its class. With fully rated power, this modular 3 phase UPS delivers maximum power capacity, better power protection and quality to the load. Scalability, availability, and efficiency distinguish the Modulon DPH Series UPS as the best solution for power protection and distribution in your datacenters.

The Modulon DPH is designed in modern IT aesthetics aligned with Delta InfraSuite datacenter solutions.
▲ The Modulon DPH is designed in modern IT aesthetics
aligned with Delta InfraSuite datacenter solutions.

 

Applications: Datacenter Telecom Industrial Network Security Lab Medical Metro Banking

UPS DPH Series - features

Delta- DPH Series Applications


Features

Ultimate Availability

  • Advanced fault-tolerant design achieved by self redundancy to guarantee operation continuity
  • Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure
  • Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero without downtime risk
  • Wide input voltage range of -45% to +25% and narrow output voltage regulation window to cope with harsh utility conditions and seamlessly provide stable power supply to the load
  • High overload protection to support 125% overload for 10 minutes and 150% for 1 minute

High Scalability

  • Vertical expansion from 25kW to 75/150/200kW supporting N+X redundancy in a single rack enclosure to save footprint
  • Parallel expansion up to four units without requiring additional hardware
  • Variable configurations possible providing the scalable flexibility up to Tier 4 standard
  • Excellent Power Performance and Efficiency
  • Fully rated power (kVA=kW) to maximize power availability
  • High AC-AC operating efficiency of 95% at 30% light load and 96% from 50% load resulting in marked energy cost savings
  • Low harmonic pollution (iTHD<3%) to reduce upstream investment costs and meet demanding power requirements

Easy Maintenance

  • Built-in manual bypass features to eliminate maintenance-related downtime
  • Proactive detection of fan failure and switch fault for early diagnosis on UPS malfunction
  • Plug and play to simplify the maintenance process

Technical Specifications

Model DPH 75kW System
DPH 150kW System
DPH 200kW System
Power Rating
DPH 75kW System 25, 50, 75 kVA
DPH 150kW System 25, 50, 75, 100, 125, 150 kVA
DPH 200kW System 25, 50, 75, 100, 125, 150, 175, 200 kVA
Frame
DPH 75kW System 75 kW
DPH 150kW System 150 kW
DPH 200kW System 200 kW
Input
Nominal Voltage 380/220V, 400/230V, 415/240V (3 phase, 4-wire +G)
Voltage Range 176~276 / 305~477 Vac *
Current Harmonic Distortion < 3% **
Power Factor > 0.99
Frequency 50/60 Hz ***
Output
Voltage 380/220V, 400/230V, 415/240V (3 phase, 4-wire +G)
Output Power Factor 1 (kVA=kW)
Voltage Harmonic Distortion ≦ 2% (linear load)
Voltage Regulation ± 1% (static)
Frequency 50 or 60 Hz
Frequency Regulation ± 0.05 Hz
Overload Capacity ≦ 125%: 10 minutes
≦ 150%: 1 minute
Interface
Standard System communication port x 1, LCM port x 1, Parallel port x 2, Smart slot x 2, Output dry contact x 6, Input dry contact x 2, Battery dry contact x 2, REPO
Optional SNMP IPv6 card, ModBus card, Relay I/O card,
Battery cabinet temperature sensor cable, Battery cabinet status detection kit
Conformance
Safety & EMC BSMI, CE, EN62040-1
Other Features
Parallel Redundancy and Expansion Module and system redundancy
Maximum 4 units
Emergency Power Off Local and remote
Battery start Yes
Event Log 3000 records
Efficiency
AC-AC 96% (Tested by TÜV)
ECO Mode 99%
Environment
Operating Temperature 0 ~ 40 ˚C
Relative Humidity 0~95% (non-condensing)
Audible Noise (at one meter) < 62 dBA
Dimensions (WxDxH) 600 x 1090 x 2000 mm
Weight
UPS System 75kW System: 310 kg
150kW System: 320 kg
200kW System: 350 kg
Power Module 75kW System: 32 kg
150kW System: 32 kg
200kW System: 32 kg
Rack-mount PDC 75kW System: 32 kg
150kW System: 32 kg
200kW System: N/A
Battery Module 75kW System: 29.5 kg
150kW System: N/A
200kW System: N/A

Download

DPH Series 25 – 75/150/200 kW UPS (Leaflet) – for EMEA, South America, SEA, Taiwan, Korea (English) Model: DPH 75kW System   /   DPH 150kW System   /   DPH 200kW System
DPH Series 25-200 kVA UPS (Brochure) Model: DPH 200kW System

Management System

User-friendly Control InterfaceDesigned for management ease, the Modulon DPH is fully equipped with user-friendly monitoring and controls in various languages. A big graphic LCD screen provides the needed control for all communication and command options at the tip of your fingers to monitor and control functions on a single page view. Direct event log viewing helps quickly diagnose events without additional hardware requirements. Up to 3,000 event logs can be recorded.

Integrated Monitoring and ManagementDelta UPSentry 2012 communicates with UPS through physical interface RS232 and USB for UPS manageability. Also works with Shutdown Agent 2012 to protect a group of PCs, workstations, or servers. Delta New Shutdown Agent cooperates with SNMP card or UPSentry 2012 to shut down multi-servers in various operating system and virtual machine gracefully to prevent possible data corruption. Furthermore, Modulon DPH can be monitored and controlled together with other datacenter equipment by Delta InfraSuite Manager (EMS 3000) as a total datacenter control and monitoring solution.

Intelligent Battery Management SystemDelta intelligent battery management system can sustain battery lifespan and the
capacity of battery backed up through the functions of:

  • Battery temperature monitoring & compensation
  • Battery remaining capacity displayed in percentage
  • Overcharge/discharge protection
  • Boost/float stage charge
  • Auto/manual battery test
  • Adjustable charging voltage from 254V to 291V adapts to different types of batteries
  • Up to 40A charging current even at full load conditions
    38~42 battery units in one battery cabinet optimizes investment