RT Series, 5/6/10 kVA

Single Phase

The Amplon RT series delivers double-conversion on-line technology, high power density and input power factor, and low current harmonics with its advanced architecture. Designed in a rack or tower configuration with an LCD display, Amplon RT offers advanced performance for servers, data centers, networking, VoIP and telecommunications.

The Amplon RT has 1+1 parallel redundancy function to provide higher reliability. Optional external battery pack can be added to fulfill longer backup time for mission critical applications.

Applications: Server Telecom Industrial Network VolP Storage Medical

RCM compliance

  • True online double-conversion topology provides 24/7 fulltime protection.
  • 1+1 parallel redundancy or expansion without requiring additional hardware.
  • AC-start and battery-start capabilities.
  • Additional charger board can be added to reduce recharging time.
  • Optional maintenance bypass box for parallel redundancy with manual bypass switch.
  • External charger box enhances battery charging ability.
  • Rack or tower configuration.
  • Multi-language LCD display with blue backlight.
  • Optional external battery pack for longer backup time.
  • Output factor 0.9 delivers more real power.
  • High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%).
  • Common battery installation enables two UPS in parallel to share one battery source for cost savings.
  • Wide input voltage range reduces battery discharging occurrence and prolongs battery lifetime.
 Model
RT-5K / RT-6K / RT-10K
 Power Rating
[5K]: 5kVA/4.5kW
[6K]: 6kVA/5.4kW
[10K]: 10kVA/9kW
 Input
 Nominal Voltage
200/208/220/230/240 Vac (single phase)
 Voltage Range
100~300Vac *
 Current Harmonic Distortion
< 5% (full load)
 Power Factor  > 0.99 (full load)
 Frequency
40 – 70 Hz
 Power Factor
> 0.97
 Electrical Connection
Terminal block
 Output
 Voltage 200/208/220/230(default)/240 Vac (single phase)
 Voltage Harmonic Distortion  < 2% (linear load)
 Voltage Regulation
± 1% (static)
± 2% (typical)
 Frequency
50 or 60 ± 0.05 Hz
 Overload Capability
106 ~ 110%: 10 minutes
111 ~ 125%: 5 minutes
126 ~ 150%: 30 seconds
 Electrical Connection
Terminal block
 Crest Factor
 3:1
 Battery & Charger
 Nominal Voltage
[5K]: 192 Vdc
[6K]: 192 Vdc
[10K]: 240 Vdc
 Charge Current
Built-in: maximum 4A (adjustable)
Additional charger board (optional)  maximum 4A (internal installation)
 Electrical Connection
Exclusive cable
 Interface
 Standard
RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1
 Conformance
 Safety & EMC
CE, TUV, EN62040-1
CISPR 22 Class A
 Other Features
 Parallel Redundancy
 1+1
 Remote Control
 REPO, Remote On/Off
 Common Battery Installation
 Yes
 Efficiency
 AC-AC  92% (full load)
 ECO Mode  96% (full load)
 Environment
 Operating Temperature  0 ~ 40ºC
 Relative Humidity  0 ~ 95%
 Audible Noise (at one meter) 54 dBA **
 Physical
 Dimensions (WxDxH) [5K]: 440 x 671 x 89 mm
[6K]: 440 x 671 x 89 mm
[10K]: 440 x 623 x 131 mm
 Battery Pack  Dimensions(WxDxH) [5K]: 440 x 638 x 89 mm
[6K]: 440 x 638 x 89 mm
[10K]: 440 x 595 x 131 mm
 Weight [5K]: 15 kg
[6K]: 15.5 kg
[10K]: 21.3 kg
 Battery Pack Weight
[5K]: 36 kg
[6K]: 36 kg
[10K]: 66 kg
* For 5 and 6 kVA models, lower range 100 ~ 155 Vac is acceptable under 50 ~ 100% loading condition.
For 10 kVA model, lower range 100 ~ 180 Vac is acceptable under 50 ~ 100% loading condition.
** Audible Noise is at 70% load.

All specifications are subject to change without prior notice.